Here's the detailed technical specification for Emerson PR6423-002-021, a key component in machinery health monitoring systems:
Emerson PR6423-002-021
Eddy Current Displacement Transducer System
(5mm Probe, 5m Integrated Cable)
Part Number Breakdown
Segment Meaning
PR6423 Eddy current transducer series
-002 5mm probe diameter × 25mm sensing area
-021 5-meter integrated cable + M20 connector
Key Specifications
Parameter Specification
Probe Tip Ø5mm, epoxy-filled, temperature-stabilized coil
Operating Principle Electromagnetic eddy current (non-contact)
Measurement Range 0.5–2.5mm (optimized for 1.0mm gap)
Sensitivity 8.0 mV/µm (±5%) at 1kHz, carbon steel target
Linearity Error <±1% FS (over 0.5–2.5mm range)
Frequency Response 0–10kHz (±3dB)
Temp. Range Probe: -30°C to +150°C (non-condensing)
Cable 5m integral CA6423 low-noise coaxial (FEP jacket)
Connector M20×1.5 stainless steel
Output Signal Requires CON021/CON041 converter (-2 to -18V DC)