The Emerson PR6426/0R0-030 is a specialized intrinsically safe (IS) eddy-current proximity probe designed for hazardous environments where explosive gases or dust may be present. Here are its detailed specifications and applications:
Key Specifications
Parameter Details
Model PR6426/0R0-030
Type Intrinsically Safe (IS) Eddy-Current Sensor
Certifications ATEX, IECEx (Class I, II, III Div 1) for hazardous areas
Measurement Range 0 to 2 mm (calibration-dependent)
Output Signal -2 to -18V DC (linear to gap distance)
Power Supply -24V DC via IS barrier (e.g., Bently Nevada 3300/1900-IS)
Cable Length 9 meters (30 feet) with IS-rated cable
Temperature Range -40°C to +120°C (ambient); T4 rating (≤135°C surface temp)
Frequency Response 0 to 10 kHz
Target Material Ferrous metals (e.g., AISI 4140 steel)
Applications
Oil & gas (compressors, pumps in explosive atmospheres)
Petrochemical plants
Mining equipment (dust-prone environments)
Any Zone 1/21 or Div 1 hazardous area
Key Differences vs. Standard PR6426 Models
Feature PR6426/0R0-030 (IS) PR6426/000-030 (Standard)
Safety Rating ATEX/IECEx Certified Not for hazardous areas
Power Limits Requires IS barrier Direct connection to monitor
Cable IS-rated, shielded Standard shielded cable
Installation Strict Ex-compliance General industrial use