Welcome to CW Green Tech Limited
info@cwlyautomation.com 86-136 6712 1125
Home      Products ABB 1SBL141010R8010 A9-30-10RT contactor 220-230V 50Hz / 230-240V 60Hz
ABB 1SBL141010R8010 A9-30-10RT contactor 220-230V 50Hz / 230-240V 60Hz

ABB 1SBL141010R8010 A9-30-10RT contactor 220-230V 50Hz / 230-240V 60Hz

  • Product Item : A9-30-10RT 1SBL141010R8010
  • Product Brand : ABB
  • INQUIRY

ABB 1SBL141010R8010 A9-30-10RT 220-230V 50Hz / 230-240V 60Hz


General Information

Extended Product Type:

A9-30-10RT 220-230V 50Hz / 230-240V 60Hz

Product ID:1SBL141010R8010

EAN:3471522262004

Catalog Description: A9-30-10RT 220-230V 50Hz / 230-240V 60Hz Contactor

Technical information of ABB 1SBL141010R8010 A9-30-10RT

Number of Main Contacts NO:3

Number of Main Contacts NC:0

Number of Auxiliary Contacts NO:1

Number of Auxiliary Contacts NC:0

Number of Poles:3P

Rated Operational Voltage:

Auxiliary Circuit 690 V

Main Circuit 690 V

Rated Frequency (f):

Auxiliary Circuit 50 / 60 Hz

Control Circuit 50 / 60 Hz

Rated Operational Current AC-1 (Ie):

(690 V) 40 °C 25 A

(690 V) 55 °C 22 A

(690 V) 70 °C 18 A

Rated Operational Current AC-3 (Ie):

(415 V) 55 °C 9 A

(440 V) 55 °C 9 A

(500 V) 55 °C 9 A

(690 V) 55 °C 7 A

(380 / 400 V) 55 °C 9 A

(220 / 230 / 240 V) 55 °C 9

Rated Operational Current AC-15 (Ie):

(500 V) 2 A

(690 V) 2 A

(24 / 127 V) 6 A

(220 / 240 V) 4 A

(380 / 400 V) 3 A

Rated Operational Current DC-13 (Ie):

(24 V) 6 A / 144 W

(48 V) 2.8 A / 134 W

(72 V) 2 / 144 W

(110 V) 1.1 A / 121 W

(125 V) 1.1 / 138 W

(220 V) 0.55 A / 121 W

(250 V) 0.55 / 138 W

Rated Operational Power AC-3 (Pe):

(415 V) 4 kW

(440 V) 4 kW

(500 V) 5.5 kW

(690 V) 5.5 kW

(380 / 400 V) 4 kW

(220 / 230 / 240 V) 2.2 kW

Rated Short-time Withstand Current Low Voltage (Icw):

at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 100 A

at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 26 A

at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 50 A

at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 250 A

at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 60 A

for 0.1 s 140 A

for 1 s 100 A

Maximum Breaking Capacity:

cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 250 A

cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 90 A

Rated Insulation Voltage (Ui):

acc. to IEC 60947-4-1 690 V

acc. to IEC 60947-5-1 690 V

acc. to UL/CSA 600 V

Rated Impulse Withstand Voltage (Uimp):

6 kV

Rated Control Circuit Voltage (Uc):

50 Hz 220 ... 230 V

60 Hz 230 ... 240 V

Power Loss:

at 6 A per Pole 0.1 W

at Rated Operating Conditions AC-1 per Pole 0.8 W

at Rated Operating Conditions AC-3 per Pole 0.1 W

Mounting on DIN Rail:

TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715

TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715

Mounting by Screws (not supplied):

2 x M4 screws placed diagonally