Safety integrity level:SIL 2 (IEC 61508), SILCL2 (IEC 62061)
Category:3 (EN ISO 13849)
Maximum demand rate:Continuous (analog signals)
Performance level:PL d (EN ISO 13849) 1)
PFHD: Probability of dangerous failure per hour:1.0 x 10-8 2)
Connection type:Cable, 8-wire, radial, 2 m
Supply voltage:7 V DC ... 12 V DC
Recommended supply voltage:8 V DC
Current consumption:80 mA 1)
Output frequency for sine/cosine signals:≤ 200 kHz
Dimensions:See dimensional drawing
Weight:≤ 0.2 kg
Moment of inertia of the rotor:10 gcm2
Operating speed:≤ 12,000 min?1
Angular acceleration:≤ 200,000 rad/s2
Operating torque:0.2 Ncm
Start up torque:+ 0.4 Ncm
Operating temperature range:–30 °C ... +115 °C
Storage temperature range:–40 °C ... +125 °C, without package
Relative humidity/condensation:90 %, Condensation not permitted
SRS50S-HEA0-K21
SRS50-HWA0-K22
SRS50S-HGV0-K21
SRS50-HFA0-K22
SRS50-HXA0-K22
SRS50S-HFA0-K21
SRS50-HTA0-K21
SRS50-HAV0-K21