Rosemount™ CX1100 In-Situ Oxygen Transmitter
The Rosemount™ CX1100 In-Situ Oxygen Transmitter provides a continuous, accurate measurement of the oxygen remaining in flue gases coming from a combustion process. Accurate measurements of furnace exhaust excess oxygen are critical for combustion optimization, which result in reduced energy costs, increased safety, and lower emissions. This product is intended for use for combustion applications only.
The Rosemount CX1100 probe contains a zirconia type oxygen sensor. At high temperatures, zirconia produces an electrical potential that is proportional to the difference in process oxygen concentration and ambient reference air. This voltage is transmitted to the Rosemount CX1100 remote transmitter and output as an analog signal. The sensor is mounted at the end of the probe tube which extends into a flue gas duct or stack. Varying lengths of the probe are available to achieve desired insertion depths. The probe tube also houses a heating element to precisely control the temperature of the sensor, reducing errors induced by varying process temperatures.
Specification Description
Net O2 range 0 - 23%
Repeatability 0.1% of O2 or 1.0% of reading, whichever is lower
Lowest detectable limit 0.05% O2
Process temperature effect Less than 0.3% O2 from 77 to 1292 °F (25 to 700°C)
System speed of response to calibration gas Initial response in less than 3 seconds, T90 in 10 seconds. Response to process gas changes
will vary depending on process gas velocity and
particulate loading of the diffuser.
Environmental specifications
Table 1-2: Probe
Specification Description
Probe Process wetted materials are 304 stainless steel.
Maximum process temperature 752 °F (400 °C)
Table 1-3: Probe Terminations
Specification Description
Rosemount CX1100 probe ambient temperature limits
-4 to 158 °F (-20 to 70 °C)
Table 1-4: Remote Display
Specification Description
Materials Polycarbonate
Ambient temperature limits -4 to 122 °F (-20 to 50 °C)
Model Product description
CX1100 In-Situ Oxygen Transmitter
Material
A 304L stainless steel
Probe length
050 1.64 ft. (0.5 m) oxygen probe
100 3.28 ft. (1.0 m) oxygen probe
200 6.56 ft. (2.0 m) oxygen probe
Probe mounting flange
F20 ANSI/DIN: 4.75 in. / 5.71 in. bolt circle, 0.75 in. holes
Transmitter
M7 Remote transmitter with LCD display and interface
M0 Probe only (no transmitter)
Product certification
G6 CSA ordinary location
Probe mounting hardware
N1 New installation plate - ANSI pattern
N2 New installation plate - DIN pattern
Transmitter mounting hardware
T3 2-in. pipe / wall mount kit
Calibration accessories
F1 Calibration gas flowmeter