The Yokogawa ZR802G is an intelligent online zirconia oxygen content monitoring instrument from Yokogawa Electric. The following is the specific introduction:


The technical parameters of ZR802G|006|/br/br are as follows:

- **Measurement object**

- **Oxygen analyzer**: Oxygen concentration in combustion exhaust gas and mixed gas.

- **Humidity analyzer**: Water vapor content (volume percentage) in mixed gas (air and water vapor).

- **Measurement range**

- **O₂**: 0.01-100 vol%

- **H₂O**: 0-100 vol%

- **Mixing ratio**: 0-1.000 kg/kg

- **Digital communication**

- HART 7

- Ethernet (Modbus TCP)

- RS-485 (Modbus RTU)

- **Accuracy**

- **Repeatability**

- **O₂**: ±0.5%FS in the range of 0-5 vol%; ±1%FS in the range of 0-25 vol% and above to 0-100 vol%.

- **H₂O**: ±1 vol% H₂O for sample pressure 2 kPa or less.

- **Linearity**

- **O₂**: ±1%FS in 0-5 vol% range; ±3%FS in 0-25 vol% to 0-50 vol% range; ±5%FS in 0-50 vol% and above to 0-100 vol%.

- **H₂O**: ±2 vol% H₂O within ±0.49 kPa of sample pressure; ±3 vol% H₂O for sample pressure 2 kPa or less.

- **Drift**

- **O₂**: Both zero and span drift are ±2%FS/month.

- **H₂O**: Both zero and span drift are ±3 vol% H₂O/month.

- **Response Time**: 90% response in 5 seconds.

- **Sample gas temperature**: 0-700°C (probe only); 700-1400°C (with high temperature probe adapter)

- **Sample gas pressure**: -5-250kPa

- **Output signal**: 4-20mADC

- **Material in contact with gas**: SUS316 (JIS), zirconia, SUS304 (JIS) (flange), HastelloyB (Inconel600, 601)

- **Structure**: Heater and thermocouple replaceable structure

- **Power supply voltage**: Rated 100-240VAC, acceptable range 85-264VAC

- **Power supply frequency**: Rated 50/60HZ, acceptable range 45-66Hz

- **Ambient temperature**: Separate transmitter and integrated type -20-55°C, separate probe -20-150°C


The Yokogawa ZR802G is a model in its own right, with subdivided models underneath. Depending on the configuration options, it can be subdivided into the following models:

**By converter interface**: ZR802G|01|-t-t 1/2 NPT, indicating a converter with a t1/2 NPT interface.

**By digital communication method**: ZR802G|02|-t

- ZR802G|02|-h-h HART, indicates that the HART communication protocol is used.

- ZR802G|02|-e-e HART+Modbus TCP, indicates that HART and Modbus TCP communication protocols are supported.

- ZR802G|02|-m-m HART+Modbus RTU, indicates support for HART and Modbus RTU communication protocols.

**Press other options**

- ZR802G|03|-n-n always-n and ZR802G|04|-n-n always-n, the exact meaning is not clear at this time, but it is presumed to be related to some default configurations or specific functions.

- ZR802G|001|/sct /sct indicates an analyzer with a stainless steel label plate.

- ZR802G|005|/rc/rc indicates an analyzer with a ruggedized coating (epoxy + polyurethane coating).

- ZR802G|006|/br/br indicates a wall bracket for ZR402G replacement.