Measuring principle:Capacitive
Interface measurement:Interfaces liquid / liquid also with emulsion layers
Supply / Communication:12-36V DC HART PFM
Accuracy:repeatablity 0,1%
Linearity error for conductive liquids:<0,25%
Ambient temperature:-50°C...+70°C(-58°F...+158°F)
Process temperature:-80°C...200°C(-112°F...392°F)
Main wetted parts:Insulation material: FEP,PFA 316L
Max. measurement distance:0.42 m ... 10.0 m(1.38 ft ... 33 ft)
Communication:4...20mA HART PFM
Liquicap FMI52 is a reliable fully insulated rope probe for continuous level monitoring in liquids, particularly in small tanks, build-up forming media and extremely high temperatures - especially for large measuring ranges. The measurement is independent of the dielectric constant (dc). Used in conjunction with Fieldgate FXA320 (remote measured value interrogation using Internet technology), Liquicap is an ideal solution for Inventory Management Solutions.
Device is independent of the dielectric constant (dc) as of a liquid conductivity of 100μS/cm and allows measurement of various liquids without the need for recalibration.
Process connections: Flanges and threads
Process pressure: Vacuum to +100bar (vacuum to 1,450psi)
Measuring range: 0.42 to 10.0m (1.38 to 33ft)
Temperature: -80 to +200°C (-112 to +392°F)
International explosion protection certificates, overfill prevention WHG, SIL, hygienic certificates, marine approvals
Use also in safety systems requiring functional safety to SIL2 in accordance with IEC 61508
Reliable and universal application thanks to wide range of certificates and approvals
No calibration necessary (factory preconfiguration). No calibration necessary for media with a conductivity of 100μS/cm and higher
Material in contact with the process made of corrosion-resistant material
Menu-guided local configuration via plain text display (optional)
Two-stage overvoltage protection
FMI52-A1AAHJA3A1A
FMI52-U2BGEJB1A1A
FMI52-J3ABSKB1A1A
FMI52-P1CRDJA1C1A
FMI52-A1AREJA3B1A
FMI52-A1BTDJB2A1A
FMI52-A1AGDJB3A1A
FMI52-A2BTDJB1A1A