Here is the parameter introduction of Hirschmann SPIDER 5TX in the SPIDER series:
Port Configuration
Port Types and Quantities: It is equipped with 5 x 10/100BASE - TX twisted - pair RJ45 ports. These ports support auto - crossing, auto - negotiation, and auto - polarity recognition, which means they can automatically adapt to different connection scenarios and ensure reliable data transmission.
Network Performance
Switching Mode: It adopts the store - and - forward switching mode. In this mode, the switch receives the entire data frame, checks its integrity and validity, and then forwards it to the appropriate port. This helps to ensure the accuracy and reliability of data transmission, especially in environments with potential data errors or interference.
MAC Address Table: It can learn up to 1,000 source addresses. The device monitors the age of learned addresses and deletes address entries from the address table that exceed 300 seconds. This mechanism helps to maintain the efficiency and performance of the switch by removing obsolete address information.
VLAN Tagging: It complies with the IEEE 802.1q standard, which designates the VLAN tag to be included in a MAC data frame for VLAN and prioritizing functions. This allows for the creation of virtual local area networks, enhancing network management and security.
Power Supply Parameters
Operating Voltage: The required DC power supply is 9.6V - 32V. This wide voltage range makes the switch suitable for use in various industrial power supply environments.
Current Consumption: The maximum current consumption at 24V DC is 100mA.
Power Consumption: The maximum power consumption is 2.2W at 24V DC, which is relatively low, indicating good energy efficiency.
Physical Characteristics
Dimensions: The size is 25mm x 114mm x 79mm (W x H x D), featuring a compact design that takes up little space and is easy to install in industrial control cabinets or other confined spaces.
Weight: It weighs 113g, which is lightweight and convenient for handling and installation.
Mounting Method: It can be installed on a 35 - mm DIN rail, which is a common installation method in industrial automation, facilitating quick and secure installation. The protection class is IP30, which provides a certain level of protection against dust and solid objects.