  • Product Item : SPIDER 4TX/1FX-SM EEC
  • Product Brand : Hirschmann
  • INQUIRY

Here is the parameter introduction of Hirschmann SPIDER 4TX/1FX-SM EEC in the SPIDER series:

Port Configuration:

Port Types and Quantities: It has 4 x 10/100BASE-TX twisted-pair RJ45 ports, which support auto - crossing, auto - negotiation, and auto - polarity recognition. Additionally, there is 1 x 100BASE-FX single - mode fiber port with an SC interface.

Network Performance:

Switching Mode: It adopts the store - and - forward switching mode, suitable for Ethernet (10Mbit/s) and fast Ethernet (100Mbit/s) applications.

Network Scale: The maximum length of the twisted - pair cable is 100m. For single - mode fiber, it can reach 32.5km with a 16 - dB link budget at 1300nm, an attenuation of 0.4dB/km, a 3 - dB reserve, and a dispersion of 3.5ps/(nm x km).

Power Supply Parameters:

Operating Voltage: It requires a DC power supply of 9.6V-32V. The maximum current consumption at 24V DC is 150mA, and the maximum power consumption is 3.9W (13.3Btu(IT)/h at 24V DC).

Physical Characteristics:

Dimensions: The size is 25mm x 114mm x 79mm (W x H x D).

Weight: It weighs 120g.

Mounting Method: It can be installed on a 35-mm DIN rail. The protection class is IP30.

Environmental Adaptability:

Operating Temperature: The operating temperature range is - 40°C to + 70°C, and the storage/transport temperature range is -40°C to +70°C.

Relative Humidity: The relative humidity is 10%-95% (non-condensing).

Reliability:

MTBF: The mean time between failures (MTBF) is 93.9 years, calculated according to MIL-HDBK-217F at 25°C.

EMC Performance:

Immunity: It complies with EN 61000 - 4 - 2 (6kV contact discharge, 8kV air discharge for electrostatic discharge), EN 61000 - 4 - 3 (10V/m electromagnetic field at 80 - 1000MHz), EN 61000 - 4 - 4 (2kV power line, 4kV data line for fast transients), EN 61000-4-5 (power line: 2kV (line/earth), 1kV (line/line), 1kV data line for surge voltage), and EN 61000 - 4 - 6 (10V (150kHz - 80kHz) for conducted immunity).

Emissions: It meets the requirements of FCC CFR 47 Part 15 Class A and EN 55022 Class A.

Certifications: It has the safety certification of industrial control equipment, such as cUL 508.