Measuring principle:Vortex
Nominal diameter range:DN 15 to 300 (½ to 12")
Max. process pressure:PN 100, Class 600, 20K
Sensor housing material:Sensor connection housing: AlSi10Mg, coated; 1.4408 (CF3M)
Transmitter housing material:AlSi10Mg, coated; 1.4404 (316L)
Inputs:Current Input 4‐20 mA (passive)
Digital communication:HART, PROFIBUS PA, FOUNDATION Fieldbus
Marine approvals and certificates:ABS, LR, BV, DNV
Pressure approvals and certificates:PED, CRN, AD 2000
Prowirl F is the multivariable flowmeter with inline wet steam measurement. Its calibration option PremiumCal guarantees excellent measuring accuracy and highest plant availability at low flow rates of gas, steam and liquids. With genuine loop-powered technology, Prowirl F 200 enables cost-effective and seamless integration into existing infrastructures. It offers highest operational safety in hazardous areas. Heartbeat Technology enables process safety at all times.
Preferred measuring principle for wet/saturated/superheated steam, gases & liquids (also cryogenic)
Suitable for a wide range of applications; optimized for steam applications
Device properties
Wet steam capabilities for DN 25 to 300 (1 to 12")
Flexible positioning of pressure cell
Industrial siphon design for pressure measurement
Display module with data transfer function
Robust dual-compartment housing
Plant safety: worldwide approvals (SIL, Haz. area)
Easy energy management – integrated temperature and pressure measurement for steam and gases
Reliable, secure measurement technology – compliance with international Vortex standard ISO 12764
Same accuracy down to Re 10 000 – most linear Vortex meter body
Long-term stability – robust drift-free capacitive sensor
Convenient device wiring – separate connection compartment, various Ethernet options
Safe operation – no need to open the device
Integrated verification – Heartbeat Technology