Here is a technical specification introduction to the Keyence CA-H200C/M Intuitive Vision System:
CA-H200C (Color Version)
Image Element: It uses a color CMOS image sensor with 7×/16× high - speed reading using square - pixels. The unit cell size is 4.5 µm × 4.5 µm.
Valid Pixel Count: In the 2 - megapixel mode, it is 1600 (H) × 1200 (V); in the 1 - megapixel mode, it is 1024 (H) × 960 (V). The image size is equivalent to 1/1.8 inches.
Scanning System: It adopts a progressive scanning system. At 7× transfer speed, it is 28.9 ms; at 16× transfer speed, it is 11.8 ms.
Pixel Transfer Frequency: At 7× transfer speed, it is 86 MHz (43 MHz × 2); at 16× transfer speed, it is 198 MHz. The transfer system is digital serial transfer.
Electronic Shutter: It can be set to 0.05 to 9000 msec by specifying numerical inputs such as 1/15, 1/30, 1/60, etc.
Lens Mount: It has a C - mount.
Enclosure Rating: It has an IP64 rating. However, a Keyence - specified IP64 - rated lens and environment - resistant cable must be used.
Environmental Resistance: The ambient temperature range is 0 to 45 °C, and the relative humidity is 35 to 85% RH.
Weight: It weighs approximately 75 g (excluding the lens).
CA-H200M (Monochrome Version)
Image Element: It is a monochrome CMOS image sensor with 7×/16× high - speed reading using square - pixels. The unit cell size is 4.5 µm × 4.5 µm.
Valid Pixel Count: The 2 - megapixel mode is 1600 (H) × 1200 (V), and the 1 - megapixel mode is 1024 (H) × 960 (V). The image size is equivalent to 1/1.8 inches.
Scanning System: It is a progressive scanning system. The scanning time is 28.9 ms at 7× transfer speed and 11.8 ms at 16× transfer speed.
Pixel Transfer Frequency: At 7× transfer speed, it is 86 MHz (43 MHz × 2), and at 16× transfer speed, it is 198 MHz. The transfer system is digital serial transfer.
Electronic Shutter: It can be set from 0.05 to 9000 msec with numerical inputs like 1/15, 1/30, 1/60, etc.
Lens Mount: It has a C - mount.
Enclosure Rating: It is IP64 - rated, and a Keyence - specified IP64 - rated lens and environment - resistant cable are required.
Environmental Resistance: The operating ambient temperature is 0 to 45 °C, and the operating ambient humidity is 35 to 85% RH.
Weight: It weighs about 75 g (excluding the lens).