Home      Products Danfoss FC102P200T4E00H2XGX AutomationDrive frequency converters
Danfoss FC102P200T4E00H2XGX AutomationDrive frequency converters

Danfoss FC102P200T4E00H2XGX AutomationDrive frequency converters

  • Product Item : FC102P200T4E00H2XGX
  • Product Brand : Danfoss
  • INQUIRY

Here is the technical parameter introduction of Danfoss FC102P200T4E00H2XGX:

Power Parameters: The rated power is 200 kW, and the rated current is 395 A at 480 V. It is suitable for three - phase power supply with a voltage range of 380 - 480 V.

Control Principle: It adopts the EC + intelligent VVC + control principle, which is applicable to permanent - magnet motors and synchronous reluctance motors. It also supports AMA and AEO. AMA optimizes motor control, and AEO optimizes the motor's magnetization state under all speed and load conditions, improving energy efficiency by 5 - 15% under non - full - load conditions.

Enclosure and Protection: The protection level can reach IP55/NEMA 12, which is suitable for harsh industrial environments.

Built - in Functions:

PID Controller: It is equipped with 4 auto - tuned PID controllers, which can quickly and accurately adjust the controlled system to make it stable.

Fire - control Mode: In the fire - control mode, the drive will ignore control signals, warnings, or alarms to ensure the normal operation of the HVAC system in case of fire and help people evacuate safely.

Dry - pump Detection: It can detect the dry - pump condition by monitoring the pressure and flow of the pump, preventing damage to the pump due to dry - running.

Constant - torque Function: It can provide constant - torque output to meet the requirements of different loads.

Flow Compensation: By placing sensors near the outlet of fans or pumps, flow compensation can be carried out to save energy and reduce installation costs.

Sleep Mode: The drive can detect low - flow or no - flow conditions. It will increase the system pressure for a short time and then stop to save energy. When the pressure drops below the lower limit set point, the drive will automatically restart.

Communication: The standard built - in communication protocols include FC protocol and Modbus RTU. Optionally, it can support VLT® LonWorks MCA 108, VLT® BACnet/IP MCA 125, VLT® BACnet MCA 109, VLT® DeviceNet MCA 104, VLT® PROFIBUS DP MCA 101, etc., to meet the communication needs with different building management systems.

I/O Interfaces:

Digital Input: There are 6 programmable digital inputs, with logic of PNP or NPN and a voltage level of 0 - 24 VDC. 2 of them can be used as digital outputs.

Analog Input: There are 2 analog inputs, which can be configured as voltage or current mode. The voltage level is 0 - 10 V (adjustable), and the current level is 0/4 - 20 mA (adjustable).

Analog Output: There is 1 programmable analog output with a current range of 0/4 - 20 mA.

Relay Output: There are 2 programmable relay outputs (240 VAC, 2 A and 400 VAC, 2 A).