Siemens 3TS2500-0XM0 3TS Converter duty contactor

Siemens 3TS2500-0XM0 3TS Converter duty contactor

  • Product Item : 3TS2500-0XM0
  • Product Brand : ABB
  • INQUIRY

Here is the parameter introduction of Siemens 3TS2500-0XM0:

Rated Current: The rated current is 6A, suitable for circuits where the load current is within this range.

Control Coil Voltage: Usually, the control coil operates at 220V AC. This standard voltage allows for easy integration into most industrial power supply systems, ensuring reliable activation and de - activation of the contactor.

Rated Voltage: The rated insulation voltage is 690V, suitable for use in three - phase AC circuits with a maximum working voltage of 690V.

Frequency: It is designed for AC 50Hz or 60Hz power supply systems.

Auxiliary Contacts: It is equipped with 1 normally open (NO) and 1 normally closed (NC) auxiliary contact. These auxiliary contacts are useful for various control and signaling purposes, such as providing feedback signals to indicate the contactor's status, enabling interlocking with other electrical components, or controlling additional related circuits.

Overall Structure:

Motion Mechanism: The contactor adopts a direct - acting motion mechanism with double - break contacts and has three pairs of normally open main contacts.

Connection Mode: The contact support and the armature are elastically locked and connected, eliminating weak links. The action mechanism is flexible, and manual inspection is convenient.

Structure Design: The compact structure design can prevent foreign matter and dust from entering the moving parts, and the wiring terminals are covered to prevent direct human contact with live parts.

Installation Method: The installation method can be either rail - mounted or screwed - down, providing flexibility in different installation scenarios. Compared with other similar products, it has a higher operating frequency and control capacity.

Surrounding Environment Requirements:

Temperature: The ambient temperature is - 25℃ - + 55℃.

Humidity: The relative air humidity does not exceed 50% at + 40℃; a higher relative humidity is allowed at lower temperatures.

Altitude: The altitude does not exceed 2000m.

Atmospheric Conditions: There should be no explosive - hazard media, nor any gases and conductive dust that can corrode metals and damage insulators. The contactor should be installed in a place without significant shaking, impact, vibration, rain, or snow.

Control Voltage Range: The allowable variation range of the control voltage is 0.8 - 1.1Us.