The IndraDrive Cs (HCS01) compact converters cover the lower kW range of the power range. They combine power and control units in a single unit, and offer Ethernet-based communication, a multi-encoder interface, and integrated safety technology.
Compact design for single-axis applications
Cooling type:internal air cooling
Maximum current [A]:28
Control unit power:BASIC
Continuous current [A]:11.52
Operating panel:with standard control panel, firmware must be ordered separately
Predefined communication protocol:EtherCAT SoE; EtherCAT CoE; Sercos 3; ProfiNet IO; EtherNet/IP
Interface encoder 1:Multi-encoder interface
Safety function:Safe Motion S4
Width [mm]:70
Height [mm]:220
Depth [mm]:268
International protection code:IP20
Nominal mains frequency [Hz]:50-60
Maximum power (without choke) [kW]:6.2
Continuous power (without choke) [kW]:2.6
Max. power (with power choke) [kW]:9.7
Continuous power (with power choke) [kW]:4
max. output frequency (@4 kHz switching frequency) [Hz]:0-400
max. output frequency (@8 kHz switching frequency) [Hz]:0-800
max. output frequency (@12 kHz switching frequency) [Hz]:0-1200
max. output frequency (@16 kHz switching frequency) [Hz]:0-1600
Power supply voltage (3 AC) [V]:200-500
Output voltage:3 x AC 0 ... 500 V
Interface encoder 2:not defined
Weight [kg]:2.22