NOTIFIER fire alarm systems modules in stock with good price
NOTIFIER offers a variety of fire modules with different functions to meet various needs in fire alarm systems.
Here are some introductions and model examples:
Control Modules
FCM-1: It is an intelligent addressable control module. It performs supervised monitoring on the wiring of load devices that need external power supply, such as horns, strobes, or bells. It supports Class A and Class B supervision. It can be activated manually or through panel programming, and has the characteristics of SEMS screws for easy wiring, panel - controlled status LED, analog communication, rotary address switches, and low standby current.
CMX-7D: The module has a built - in model recognition system, and the control panel can automatically identify it as CMX - 7D. It is directly powered by the loop without additional power supply, has strong anti - interference ability, and is equipped with SEMS screws with clips for convenient wiring. The decimal address (101 - 199) is set by the CP900M electronic encoder, and the module LED indicator light can be controlled by the controller to be off, flashing, or constantly on.
Monitor Modules
FMM-1: It is used for Class A supervised wiring to the monitored device. It has the functions of built - in type identification, which can automatically identify the device as a monitor module to the control panel, SEMS screws with clamping plates for easy wiring, direct - dial entry of address: 01 - 159, and LED indication for normal or off - normal indication.
FZM-1: It is a zone interface monitor module that transmits the status of one zone of 2 - wire detectors to the fire alarm control panel. The status conditions are reported as normal, open, or alarm. It has the same features as other monitor modules in terms of address setting and wiring convenience.
Fault Isolator Module
ISO-X: It automatically isolates the short - circuit between wires in the SLC loop. When a short - circuit fault occurs in the SLC loop, it can limit the number of detectors affected by the fault. After the short - circuit is eliminated, it will automatically reconnect the isolated part of the SLC loop. It is directly powered by the SLC loop without additional power supply, and has the characteristics of LED indication, easy - to - install and - maintain SEMS-type screw terminals, and automatic reset after short - circuit elimination.
Other Modules
HTEL-PJ: It is a bus-type fire-phone module with a working voltage of 24V on the bus, a working temperature range of - 10 - 50 ° C, and a relative humidity of less than or equal to 95%. Its appearance size is 86mm * 86mm * 43mm (including the base).